beautypg.com

Deleting end-to-end monitors, Monitoring filter-based performance – HP Brocade 4Gb SAN Switch for HP BladeSystem p-Class User Manual

Page 149

background image

Fabric OS 5.0.0 procedures user guide 149

To set and display an end-to-end mask:

The end-to-end mask is set on slot 1, port 11.

To display a monitor, use the

perfmonitorshow

command, as described in ”

Displaying monitor

counters

” on page 153.

Deleting end-to-end monitors

Use the

perfdeleemonitor

command to delete end-to-end monitors. You can delete all monitors or

specific monitors. The following example deletes the end-to-end monitor number 0 on slot 1, port 2:

Monitoring filter-based performance

Filter-based performance monitoring counts the number of times a frame with a particular pattern is

transmitted by a port. Filter-based monitoring is achieved by configuring a filter for a particular purpose.

The filter can be a standard filter (for example, a SCSI Read command filter that counts the number of SCSI

Read commands that have been transmitted by the port) or a user-defined filter customized for your

particular use.

For HP StorageWorks SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, Core Switch 2/64,

and SAN Director 2/128, the maximum number of filters is eight per port, in any combination of

standard filters and user-defined filters.

For the SAN Switch 4/32, the maximum number of filters is 12 per port, in any combination of standard

filters and user-defined filters.

The actual number of filters that can be configured on a port depends on the complexity of the filters. For

trunked ports, the filter is configured on the trunk master.

You can monitor filter-based performance using the

perfmonitorshow

command, as described in

Displaying monitor counters

” on page 153. You can clear filter-based counters using the

perfmonitorclear

command, as described in

Clearing monitor counters

” on page 155.

switch:admin> perfsetporteemask 1/11, “00:00:ff” “00:00:ff” “00:00:ff”
“00:00:ff”

The EE mask on port 11 is set and EE counters are reset.

switch:admin> perfshowporteemask 1/11

The EE mask on port 11 is set by application TELNET

TxSID Domain: off
TxSID Area: off
TxSID AL_PA: on
TxDID Domain: off
TxDID Area: off
TxDID AL_PA: on
RxSID Domain: off
RxSID Area: off
RxSID AL_PA: on
RxDID Domain: off
RxDID Area: off
RxDID AL_PA: on

switch:admin> perfdeleemonitor 1/2, 0

End-to-End monitor number 0 deleted