To enable interoperability mode:
1.
Verify that you have implemented all the HP StorageWorks prerequisites necessary to enable
interoperability mode on the fabric (see ”
2.
Connect to the switch and log in as admin.
3.
Issue the
switchdisable
command to disable the switch.
4.
Issue the
configure
command to set the domain ID to a number in the range from 97 to 126. (For
detailed instructions, see ”
5.
Issue the
interopmode 1
command to enable interoperability. This command resets a number of
parameters and enables interactive mode.
6.
Reboot the switch after changing the interoperability mode.
Example:
7.
Repeat
on all HP StorageWorks switches in the fabric.
8.
Enable interoperability on each non-HP StorageWorks switch. (Refer to the switch documentation.)
9.
After enabling interoperability mode on all switches, physically connect the non-HP switches into the
HP StorageWorks fabric, one at a time.
To disable interoperability mode:
1.
Connect to the switch and log in as admin.
2.
Issue the
switchdisable
command to disable the switch.
3.
Issue the
interopmode 0
command to disable interoperability. This command resets a number of
parameters and disables interactive mode.
4.
Reboot the switch after changing the interoperability mode.
switch:admin> switchdisable
switch:admin> configure
Configure...
Fabric Parameters (yes, y, no, n): [no] y
Domain (1...239): [1] 97
...
switch:admin> interopmode 1
The switch effective configuration will be lost when the operating mode
is changed; do you want to continue? (yes, y, no, n): [no] y
done.
Interopmode is enabled
Note: It is recommended that you reboot this switch for the new change
to take effect.
switch:admin>