beautypg.com

Table 23 advanced performance monitoring commands, 23 advanced performance monitoring commands, Table 23 – HP Brocade 4Gb SAN Switch for HP BladeSystem p-Class User Manual

Page 144

background image

144 Administering advanced performance monitoring

NOTE:

The command examples use the

slot/port

syntax required by the Core Switch 2/64 and the

SAN Director 2/128. For HP StorageWorks SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32,

and SAN Switch 4/32, use only the port number where needed in the commands.

Table 23

Advanced performance monitoring commands

Command

Description

perfaddeemonitor

Add an end-to-end (EE) monitor to a port.

perfaddipmonitor

Add an IP monitor to a port.

perfaddreadmonitor

Add a SCSI Read monitor to a port.

perfaddrwmonitor

Add a SCSI Read and Write monitor to a port.

perfaddscsimonitor

Add a SCSI traffic frame monitor to a port.

perfaddusermonitor

Add a user-defined monitor to a port.

perfaddwritemonitor

Add a SCSI Write monitor to a port.

perfcfgclear Clear

the

performance monitoring settings from

nonvolatile memory.

perfcfgrestore

Restore performance monitoring settings from

nonvolatile memory.

perfcfgsave

Save the current performance monitoring settings

to nonvolatile memory.

perfclralpacrc

Clear an AL_PA device CRC count by the port and

AL_PA.

perfdeleemonitor Delete

an

end-to-end monitor on port.

perfdelfiltermonitor

Delete a filter-based monitor.

perfmonitorclear

Clear statistics counters of end-to-end, filter-based,

and ISL monitors on a port.

perfmonitorshow

Display end-to-end, filter-based, and ISL monitors

on a port.

perfsetporteemask

Set overall mask for end-to-end monitors.

perfshowalpacrc

Display the AL_PA CRC count by port or by

AL_PA.

perfshowporteemask

Display the current end-to-end mask of a port.