Viewing equipment status, To display the status of the fans – HP Brocade 4Gb SAN Switch for HP BladeSystem p-Class User Manual
Page 171
Fabric OS 5.0.0 procedures user guide 171
Viewing equipment status
You can display status for fans, power supply, and temperature.
NOTE:
The number of fans, power supply units, and temperature sensors depends on the switch type.
For detailed specifications on these components, refer to the switch hardware reference manual. The
output from the status commands varies depending on the switch type
To display the status of the fans:
1.
Connect to the switch and log in as admin.
2.
Issue the
fanshow
command:
The possible status values are:
bad eof
Frames with bad end-of-frame delimiters.
enc out
Encoding error outside of frames.
disc c3
Class 3 frames discarded.
link fail
Link failures (LF1 or LF2 states).
loss sync
Loss of synchronization.
loss sig
Loss of signal.
frjt
Frames rejected with F_RJT.
fbsy
Frames busied with F_BSY.
Table 26
Error summary description (continued)
Error type
Description
switch:admin> fanshow
Fan 1 Status: OK Set_Speed: NORMAL Actual_speed: 7010 RPM
Fan 2 Status: OK Set_Speed: NORMAL Actual_speed: 7180 RPM
Fan 3 Status: OK Set_Speed: NORMAL Actual_speed: 7068 RPM
Fan 4 Status: OK Set_Speed: NORMAL Actual_speed: 7116 RPM
Fan 5 Status: OK Set_Speed: NORMAL Actual_speed: 7155 RPM
Fan 6 Status: OK Set_Speed: NORMAL Actual_speed: 7001 RPM
switch:admin>
•
OK
Fan is functioning correctly.
•
Absent
Fan is not present.
•
Below minimum
Fan is present but rotating too slowly or stopped.
•
Above minimum
Fan is rotating to fast.
•
Unknown
Unknown fan unit installed.
•
FAULTY
Fan has exceeded hardware tolerance.