Virtual Connect networks 97

when creating or editing a profile. When this check box is selected, server network connections can only be

selected from a single shared uplink set.
When the 'Force server connections to use same VLAN mappings as shared uplink sets' check box is not

selected, server network connections can be selected from any VC Ethernet network and the external VLAN

ID mappings can be manually edited. However, administrators must ensure that no server connection VLAN

ID conflict exists.
The 'Force server connections to use the same VLAN mappings as shared uplink sets' check box can be

selected if no server profile connections are assigned to multiple networks that are not linked to a shared

uplink set.

VLAN Capacity

When creating a new domain in VC 3.70 or higher, the option to select Legacy VLAN Capacity mode is

disabled and reverting from Expanded VLAN Capacity mode back to Legacy VLAN Capacity mode is not
allowed. Domains that are upgraded from VC 3.30 that contain the Legacy VLAN Capacity mode setting are

upgraded to Expanded VLAN Capacity mode as part of the VC 3.70 or higher firmware upgrade. To

maintain compatibility with VC 3.30 domains that have Legacy VLAN Capacity mode enabled, the VCM CLI

maintains the current functionality for the VLAN mode. This also allows the use of existing scripts that
manipulate the VLAN capacity.
Expanded VLAN Capacity mode allows up to 1000 VLANs per domain. The number of VLANs per shared

uplink set is restricted to 1000. In addition, up to 162 VLANs are allowed per physical server port, with no

restriction on how those VLANs are distributed among the server connections mapped to the same physical
server port. There is also a limit of 162 VLANs per server connection. However, you must take care not to

exceed the limit per physical server port. For example, if you configure 150 VLAN mappings for a server

connection (FlexNIC-a) of a Flex-10 physical server port, then you can only map 12 VLANs to the remaining

three server connections (FlexNIC-b, FlexNIC-c, and FlexNIC-d) of the same physical server port. If you
exceed the 162 VLAN limit, the physical server port is disabled and the four server connections are marked

as Failed.

Multiple Networks Link Speed Settings

When using mapped VLAN tags (multiple networks over a single link), these settings are used for the overall

link speed control. Select the checkbox next to each item to set the value.
These settings affect only newly created profiles.
Versions of VC prior to v4.01 used the "preferred speed" to control bandwidth allocation. When existing

profiles are upgraded to VC v4.01, the "maximum speed" from the network is set automatically on the

connection. If no maximum speed was configured prior to the upgrade, then the maximum speed will be 10

Gb for Ethernet connections and 8Gb for FCoE connections. The pre-4.01 behavior can be retained by
setting "maximum speed" to the same value as "preferred speed".

IMPORTANT:

Depending on the NIC firmware versions in use, you might need to upgrade the

NIC firmware for these speed enforcement settings to work correctly.

To change these settings:

1.

Click the selection box, and then select a setting (100Mb to 10Gb):

o

Set preferred connection speed. This value is the default speed for server profile connections
mapped to this network. The server administrator can increase or decrease this setting on an

individual profile connection.