Virtual Connect server profiles 165

3.

Auto. Choosing "Auto" evenly distributes the available bandwidth between all connections assigned to

"auto".

4.

Disabled. VC determines the bandwidth speed.

For more information, see "Bandwidth assignment (on page

171

)."

Although the Port Speed Setting is available for all network connections in a profile, Virtual Connect can only

control link speed for Flex-10 NICs when they are connected to an HP Virtual Connect Flex-10 Module.

Virtual Connect cannot control the link speed of traditional NICs. Enabling specification of port speed
regardless of the underlying NIC allows the profile to configure the connection automatically when moved to

or from Flex-10 enabled servers and NICs.
Even though the system might not prompt for a server reboot, a server reboot is required after the server is

upgraded successfully with the latest firmware and drivers for HP Dual Port Flex-10 10GbE Multifunctional

BL-c Adapters, NC532i adapters, or NC532m adapters. The reboot enables the newly upgraded drivers
and boot code to run, which then enables Virtual Connect to configure the "Dynamic Changes to FlexNICs"

feature.

The Allocated Port Speed (Min-Max) column displays "not allocated" until the profile is assigned to a device

bay that contains a server. At that time, bandwidth is allocated to each connection and the result is reported
in this column. See "Bandwidth assignment (on page

171

)."

The Mapping column describes how each connection of a profile is assigned to physical devices in a server

and to which interconnect bay that device is connected. The four FlexNICs on port 1 of a server LOM that

supports Flex-10 are numbered LOM:1-a, LOM:1-b, LOM:1-c, and LOM:1-d, or LOM1:1-a, LOM1:1-b,
LOM1:1-c, and LOM1:1-d for Gen8 server blades. If a LOM does not support Flex-10, then it is simply

referenced by its port number (for example, LOM:1 or LOM:2).

FlexFabric overview

VC 3.15 and higher supports the HP VC FlexFabric 10Gb/24-port Module. This module provides eight

uplinks, four of which can be designated as either Fibre Channel or Ethernet. The remaining 4 uplinks are

Ethernet-only. It is possible to include one FC connection and three Ethernet connections on a single 10Gb

port. However, both the server and switch hardware must support FlexFabric. In addition to the existing NICs
and LOMs, this module functions with FlexFabric mezzanine cards and embedded FlexFabric LOMs.