HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 38
Virtual Connect domains 38
•
The Cause string indicates why an object transitioned to the current managed state from the specific
objects perspective. A network failure is an example Cause string.
•
The RootCause string indicates the root causes for an object transitioning managed states. The
RootCause for a network failure could indicate all uplink ports of the network have failed.
•
The ReasonCode provides an object specific reason for the managed state transition. The reason codes
are unique between objects, allowing more specific actions to be taken programmatically from SNMP
management stations.
vcDomainManagedStatusChanged
The following is an example of a domain Cause string:
2 of 7 profiles contain unmapped connections in the domain
The following is an example of a domain RootCause string:
Modules not redundantly connected, failure of module enc0:iobay1 or
enc0:iobay2 or enc1:iobay2 will isolate some modules; Port enc0:iobay5:d3:v1
loop detected and automatically disabled
The domain managed status ReasonCodes are provided in the following table.
Domain reason code
Description
vcDomainOk
All enclosures and profiles are normal in the domain.
vcDomainAbnormalEnclosuresAndProfil
es
One or more enclosures and profiles are abnormal in the domain.
vcDomainSomeEnclosuresAbnormal
At least one enclosure is not OK or Degraded.
vcDomainUnmappedProfileConnections The profile contains connections that are not mapped to a server port.
vcDomainStackingFailed
All stacking links between one or more modules have failed.
vcDomainStackingNotRedundant
Some stacking links between one or more modules have failed, but
connectivity still exists between modules.
vcDomainSomeProfilesAbnormal
One or more profiles in the domain are abnormal.
vcDomainUnknown
The condition of the domain cannot be determined.
vcDomainOverProvisioned
More than 16 VC modules are in the domain.
vcEnclosureManagedStatusChanged
The following is an example of a enclosure Cause string:
2 of 6 Ethernet modules are abnormal in enclosure enc0
The following is an example of a enclosure RootCause string:
Module in bay enc0:iobay3 has been removed
The enclosure managed status ReasonCodes are provided in the following table.
Enclosure reason code
Description
vcEnclosureOk
The enclosure is normal.
vcEnclosureAllEnetModulesFailed
All Ethernet modules are abnormal, none are OK or degraded.
vcEnclosureSomeEnetModulesAbnormal One or more Ethernet modules are abnormal.
vcEnclosureSomeModulesOrServersInco
mpatible
The enclosure contains incompatible modules, or configured modules
are missing.
vcEnclosureSomeFcModulesAbnormal
One or more FC modules are abnormal.
vcEnclosureSomeServersAbnormal
At least one server is in a known state and no servers are OK, or at
least one server is degraded.
- Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem