Interconnect module removal and replacement, Virtual connect modules – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 265
Virtual Connect modules 265
Interconnect module removal and replacement
Virtual Connect modules
In VC releases prior to 3.00, when a module was removed from an enclosure and was no longer in use by
the domain, it had to be removed from the domain using the "Remove from Domain" feature available in the
GUI and VCM CLI.
Starting with VC firmware version 3.00, it is no longer necessary to remove the module from the domain if
the module is not in use. In that scenario, the module is removed automatically from the domain without user
intervention.
Replacing a primary or backup VC module with a different VC module type is not allowed without first
deleting the domain.
If a module is in use and configured by the domain at the time it is physically removed from an enclosure, then
the module is marked as MISSING, and can only be replaced by a module of the same model and type. If
an in-use module is replaced by a module of a different type, then it is marked as INCOMPATIBLE by the
domain.
If a module being physically removed is the primary module of a primary bay pair, then it is marked as
MISSING and can only be replaced by a module of the same type.
A VC-Enet module is in use if any of the following conditions exist:
•
The module physically exists in an interconnect bay using VC release prior to 3.00.
•
The uplink and downlink ports of the module are being used by one or more networks, uplink sets, or
profiles.
•
Port monitoring is enabled for the interconnect module.
A VC-FC capable module is in use if any the following conditions exist:
•
The module physically exists in an interconnect bay using VC release prior to 3.00.
•
The uplink ports of the module are being used by a fabric that is being used by a profile.
•
The module is part of a FC bay group in a multi-enclosure configuration where other FC modules exist
in the bay group.
If a VC-FC module is replaced with a spare VC-FC module without powering down the servers, and if the
server has profiles assigned to it with FC connections, servers are allowed to log in for a brief period through
an uplink of the new module, provided that the uplink is connected to the fabric. Approximately 8 seconds
after discovering the new VC-FC module, VCM configures it with the correct information, mapping downlinks
to the correct uplinks. To work around this problem, power down the servers in the enclosure before
replacing or swapping FC modules. Alternatively, do not connect the VC-FC uplinks to the fabric until VCM
recognizes and configures the VC-FC module.
When adding VC interconnect modules to a VC managed enclosure, wait until the modules have been fully
integrated into the current domain before attempting to make configuration changes to the VC domain. These
changes include adding or editing networks, fabrics, profiles, and shared uplink sets. Verify that the domain
status is clear for the newly added interconnect module before making any changes to the configuration.
Modifying the configuration before the integration is complete can cause unexpected behavior such as
incorrect/invalid connections in a profile.
- Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem