Ethernet settings (mac addresses) screen – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 173
Virtual Connect server profiles 173
o
Select WWN ranges for server profiles
•
Serial Number Settings screen (on page
o
Add a serial number and UUID to server profiles
Ethernet Settings (MAC Addresses) screen
To access this screen, click the expand the Ethernet link in the left navigation tree and select MAC Addresses,
click Network Settings in the Network section of the home page, or select Ethernet Network Settings from the
Configure menu at the top of the screen.
This screen lists the MAC Address type and range that is used when creating server profiles.
The Type field identifies what MAC addresses are assigned to the server blades deployed within the Virtual
Connect environment. HP provides a number of pre-defined MAC address ranges, or you can choose to
enter a range of locally-owned MAC addresses. HP does not recommend using the server factory default
because these addresses do not move when the server profile is assigned to a new physical server blade.
VCM assigns or migrates MAC addresses for server Ethernet ports connected to VC-Enet modules. VCM also
assigns MAC addresses to server Ethernet ports that are not connected to an I/O module because VC
modules can be added later. Server Ethernet ports connected to non-VC modules retain the server factory
default MACs addresses. Only ports that have connections assigned in the server profile are assigned MAC
addresses. Any unassigned ports, which includes Flex-10 connections, retain their factory default MAC
addresses.
When using HP pre-defined or user-defined MAC address ranges, only use each range once within the same
layer 2 network to avoid multiple servers having the same MAC addresses. After MAC addresses have been
assigned as part of creating a server profile, this setting cannot be changed.
Only users with network role permissions can change this screen. No changes in MAC address ranges are
permitted after server profiles are created. You must delete all server profiles to change the MAC address
range settings.
- Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem