HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 221
Virtual Connect server profiles 221
4
Start with modules in Bays 3
and 4, create a profile (add
2 connections), install
modules into Bays 5 and 6,
then edit the profile.
Port
Connected to
1
Bay 3
2
Bay 4
3
Bay 3
4
Bay 4
—
—
Bay 3 Bay 4
Bay 5 Bay 6
—
—
Add connection is disallowed
because the current FC module
configurations do not match
the existing connections in the
profile.
This profile is not useful after
the hot-plug install. To resolve
this issue, delete connections 3
and 4, save the profile, and
then scenario 3 applies.
5
Start with modules in Bays
3–6, create a profile, install
modules into Bays 7 and 8,
then edit the profile and add
connections.
Port
Connected to
1
Bay 3
2
Bay 4
3
Bay 5
4
Bay 6
—
—
Bay 3 Bay 4
Bay 5 Bay 6
Bay 7 Bay 8
Port
Connected to
1
Bay 3
2
Bay 4
3
Bay 5
4
Bay 6
5
Bay 7
6
Bay 8
Add connection, 2 times
6
Start with modules in Bays
3–6, create a profile (add 4
connections), install modules
into Bays 7 and 8, then edit
the profile.
Port
Connected to
1
Bay 3
2
Bay 4
3
Bay 5
4
Bay 6
5
Bay 3
6
Bay 4
7
Bay 5
8
Bay 6
—
—
Bay 3 Bay 4
Bay 5 Bay 6
Bay 7 Bay 8
Add connection is disallowed
because the current FC module
configurations do not match
the existing connections in the
profile.
This profile is not useful after
the hot-plug install. To resolve
this issue, delete connections
5–8, save the profile, and then
scenario 5 applies.
7
Start with modules in Bays 5
and 6, create a profile,
install modules into Bays 3
and 4, then edit the profile.
Port
Connected to
1
Bay 5
2
Bay 6
—
—
Bay 3 Bay 4
Bay 5 Bay 6
—
—
Add connection is disallowed
because the current FC module
configurations do not match
the existing connections in the
profile.
To make this profile useful,
remove the two connections,
save the profile, and then
begin adding connections.
8
Start with modules in Bays
5–8, create a profile, install
modules into Bays 3 and 4,
then edit the profile.
Port
Connected to
1
Bay 5
2
Bay 6
4
Bay 7
5
Bay 8
—
—
Bay 3 Bay 4
Bay 5 Bay 6
Bay 7 Bay 8
Add connection is disallowed
because the current FC module
configurations do not match
the existing connections in the
profile.
To make this profile useful,
remove the two connections,
save the profile, and then
begin adding connections.
- Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem