HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 150
Virtual Connect fabrics 150
•
Multi-enclosure domain
The following table describes the columns and fields within the Define SAN Fabric screen.
Column
Description
Fabric Name
Descriptive name for the virtual fabric. Do not use spaces.
Fabric Type
The type of fabric. This option is available after a FlexFabric module port is added.
Supported fabric types are FabricAttach and DirectAttach. The default type is
FabricAttach. Select FabricAttach if the FlexFabric module is connected using
traditional SAN switches. For this fabric type, the advanced settings appear, allowing
you to change the login re-distribution and set the preferred and maximum connection
speed. Select DirectAttach if the FlexFabric module is directly connected to a supported
storage target. Login re-distribution is not applicable for a DirectAttach fabric;
however, advanced settings are available for the preferred and maximum connection
speed. After a fabric is defined, its type cannot be changed.
Login Re-Distribution
Login Re-distribution setting for the fabric. For all standard VC-FC modules, this is
always Manual. For FlexFabric modules, this can be set as described in "Login
re-distribution (on page
)" when the fabric type is set to FabricAttach.
Configured Speed
Speed of the uplink ports, available after a port has been added. Valid values once
allowed are 2Gb, 4Gb, 8Gb, and Auto. If 8Gb is chosen for the uplink speed on an FC
module that does not support 8Gb, the value is automatically translated to "Auto"
within VCM. This allows the module to connect at the highest supported speed.
Uplink Port
Number of the FC module uplink port
Enclosure
Enclosure selected for the SAN fabric.
Bay
Enclosure bay selected for the SAN fabric. Only uplinks on the same bay can be in the
same SAN fabric.
Port Status
Shows the link status, link speed, and connectivity of the port. If the port is unlinked and
no connectivity exists, the cause is displayed. For more information about possible
causes, see "Port status conditions (on page
)."
Speed
Port speed for the uplink ports in the fabric
Connected To
WWN of the principal switch on the SAN fabric that this port is connected to on the
other end
Action
Perform delete operations
- Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem