HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 275
![background image](/manuals/396882/275/background.png)
Maintenance and troubleshooting 275
•
Making modifications to a profile that affect settings on the server blade; for example, PXE
enable/disable, changing the number of connections, or changing Fibre Channel boot parameters
•
Assigning a VC-assigned serial number
The following operations do not require the server blade to be powered off:
•
Changing the network connected to an already defined Ethernet port
•
Changing the Fabric connected to a Fibre Channel port
•
Changing the speed of a Fibre Channel port
•
Assigning or unassigning server profiles, if server factory defaults are used for MAC addresses and
WWNs, BIOS Fibre Channel boot settings are used, and PXE is not being enabled or disabled (USE
BIOS for all network connections)
Exceptions for Flex-10 connection changes are specified in the following sections.
Flex-10 connection changes that require power off
Always power off server blades with Flex-10 connections in the following instances:
•
Adding a connection that is mapped to Flex-10
•
Removing a connection that is mapped to Flex-10
•
Assigning a profile to a server that maps Flex-10 connections
•
Unassigning a profile with Flex-10 connections
Flex-10 connection changes that do not require power off
With Virtual Connect v2.10 and higher, it is not necessary to power off a server blade with Flex-10
connections in the following instances:
•
Changing a connection's network:
o
From a single network to another single network
o
From a single network to multiple networks
o
From multiple networks to a single network
•
Modifying the networks or VLAN IDs in a connection with multiple networks
With Virtual Connect v2.30 and higher, it is not necessary to power off a server blade with Flex-10
connections in the following instances:
•
Changing a connection's network:
o
From "unassigned" to a single network
o
From a single network to "unassigned"
o
From "unassigned" to multiple networks
o
From multiple networks to "unassigned"
•
Changing the requested bandwidth
FCoE connection changes that require power off
•
Adding an FCoE connection to an assigned server profile
•
Removing an FCoE connection from an assigned server profile
•
Assigning a profile containing FCoE connections to a server
•
Changing FCoE boot parameters
- Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem