beautypg.com

Ethernet bay summary (mac address table) screen – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 237

background image

Virtual Connect modules 237

Ethernet Bay Summary (MAC Address Table) screen

This screen shows the MAC addresses that have been seen on the ports of the VC-Enet module. If a network

is assigned to the port, the network name appears. If a shared network is assigned to the port, the network

name and VLAN ID appear. If a LAG has formed with the uplink ports, the LAG ID appears.

The following table describes the columns within the MAC Address Table.

Column

Description

Port

Label of the port on which the MAC address was seen

Flex-10 downlinks ports are displayed as dx:vx, for example, d1:v1

MAC Address

MAC address that was seen

Type

Identifies how the address was seen (Learned or Other)

LAG

Identifies the group of ports that have been aggregated together to form an

802.3ad Link Aggregation Group. This ID is unique only within a single

VC-Enet module, meaning the same LAG ID can be used on different VC-Enet

modules, but it is only meaningful for ports within the same VC-Enet module.

Internal VLAN ID

Internal VLAN ID used by Virtual Connect Manager

Network Name

The name of the network associated with this port (downlink ports only)

LAG membership table

Relates the LAG IDs and uplink ports, which can help you understand the

information in the MAC address table

LAG ID

LAG IDs for this module

Uplink Port(s)

Uplink ports that are a member of the LAG ID