Virtual Connect modules 252

Column

Description

HBA Port

HBA port number

Server Blade

Server blade bay location

SAN Fabric

Name of the SAN Fabric connected to this port

To edit the SAN Fabric, click the SAN Fabric in the left navigation tree.

Uplink Port

A module uplink port used by the server to connect to the data center SAN

fabric

Profile

Server profile with connections to this port

HBA Port Speed

Speed setting of the HBA port

HBA Port Status

Status of the HBA port

HBA WWPN

World Wide Port Name of the port, either assigned by Virtual Connect or as

provided by the hardware

Interconnect Bay Overall Status icon definitions

Icon

Operational state Meaning

Corrective action

OK

Device is fully operational.

None

Unknown

Device operational state cannot be

determined.

Check Onboard Administrator

communication.

(blue)

Initializing

Device is initializing.

Wait until initialization is complete.
(This icon should only be seen at

startup.)

(yellow)

Degraded

Device is partially operational, but

capability is lost.

Check and correct the Onboard

Administrator error condition.

(orange)

Misconfigured

Device has a configuration error.

Correct the Virtual Connect Manager

configuration attributes.

(orange)

Incompatible

Device does not match the

configuration.

Remove the incorrect hardware. Insert

the correct module.

(orange)

No communication

Cannot communicate with the

device.

Check the physical connections and IP

address.

Missing

Device is configured but not

accessible.

Insert the correct hardware module.

Failed

Device is not operational because

of an error.

Reset the device or application, or

replace the device.

Interconnect Bay OA Reported Status icon definitions

Icon

Operational state

Meaning

Corrective action

OK

Device is fully operational.

None

Unknown

Device operational state cannot be

determined.

Check Onboard Administrator

communication.

(yellow)

Degraded

Device is partially operational, but
capacity is lost.

Check and correct the Onboard
Administrator error condition.

Failed

Device is not operational because
of an error.

Check and correct the Onboard