Double-dense mode, Managing fabrics – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 148
Virtual Connect fabrics 148
To perform a server profile migration of a SAN-booted server between enclosures directly attached to a 3PAR
storage system in the VC multi-enclosure environment, you must perform the following steps manually:
1.
Power off the server.
2.
Un-assign the server profile.
3.
Change the Primary and Secondary Target WWNs in the FC Boot Parameters section of the profile to
reflect the WWNs of the 3PAR storage array ports directly connected to the destination enclosure. For
more information about the FC boot parameters, see "Fibre Channel boot parameters (on page
)."
4.
Assign the profile to the destination location.
5.
Power on the destination server.
Double-dense mode
In double-dense mode, bays 7 and 8 must contain the same type of VC-FC or FlexFabric module as bays 5
and 6. When a fabric is created on bay 5 or 6, the corresponding uplink ports from bays 7 or 8 are also
considered part of the fabric. This allows connectivity from the B-side of the server.
Managing fabrics
Use the following screens to manage fabric settings:
•
Define SAN Fabric screen (on page
o
Define a SAN fabric, including selecting login re-distribution for SAN fabrics using HP VC
FlexFabric 10Gb/24-port Modules
•
SAN Fabrics (External Connections) screen (on page
o
View of list of SAN fabrics with external connection information
o
Add, edit, or delete a fabric
o
Redistribute logins on a SAN fabric
•
SAN Fabrics (Server Connections) screen (on page
o
View a list of SAN fabrics with server connection information
o
Delete a fabric
o
Redistribute logins on a SAN fabric
o
Define a SAN fabric
•
Edit SAN Fabric screen (on page
o
Modify a fabric name
o
Set the uplink port speed
o
Change the login re-distribution
o
Add or delete an uplink port
•
Fibre Channel Settings (Misc.) screen (on page
o
Set the time interval to wait after a link becomes unstable before automatic redistribution occurs
within the fabric
- Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem