beautypg.com

Server bay oa reported status icon definitions, Server bay vc status icon definitions – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 258

background image

Virtual Connect modules 258

Icon

Operational state Meaning

Corrective action

(orange)

configuration attributes.

(orange)

Incompatible

Device does not match the

configuration.

BIOS version level is not at a level that

supports Virtual Connect.

(orange)

No communication

Cannot communicate with the

device.

Check the physical connections and IP

address.

(orange)

Missing data

VCM is missing data about one or

more blades in the multi-blade

server.

Check that the blades and Blade Link

that comprise the multi-blade server are

installed correctly and functioning
properly.

Missing

Device is configured but not

accessible.

Insert the correct hardware module.

Failed

Device is not operational because
of an error.

Reset the device or application, or
replace the device.

Server Bay OA Reported Status icon definitions

Icon

Operational state

Meaning

Corrective action

OK

Device is fully operational.

None

Unknown

Device operational state cannot be

determined.

Check Onboard Administrator

communication.

(yellow)

Degraded

Device is partially operational, but

capacity is lost.

Check and correct the Onboard

Administrator error condition.

Failed

Device is not operational because

of an error.

Check and correct the Onboard

Administrator error condition.

Server Bay VC Status icon definitions

Icon

Operational state

Meaning

Corrective action

OK

Device is fully operational.

None

Unknown

Device operational state cannot be
determined.

Check Onboard Administrator
communication.

Disabled

Device is disabled.

Enable the component in Virtual

Connect Manager.

(blue)

Initializing

Device is initializing.

Wait until initialization is complete.

(This icon should only be seen at
startup.)

(blue)

Profile pending

Device has a pending profile

assignment.

Turn server power off and apply the

new profile.

(yellow)

Degraded

Device is partially operational, but

capacity is lost.

Check and correct the Onboard

Administrator error condition.

(orange)

Misconfigured

Device has a configuration error.

Correct the Virtual Connect Manager

configuration attributes.

(orange)

Incompatible

Device does not match the

configuration.

BIOS level is not at a level that supports

Virtual Connect.

(orange)

No communication

Cannot communicate with the

device.

Check the physical connections and IP

address.