Domain settings (ip address) screen – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 23

background image

Virtual Connect domains 23

CAUTION:

Deleting a domain returns all settings to factory default. This action cannot be

undone.

1.

Power off all servers that are associated with profiles. See "Server Bay Status screen (on page

260

)."

2.

Navigate to the Domain Settings (Configuration) screen (on page

22

).

3.

Click Delete. A domain name confirmation window is displayed.

4.

Enter the name of the domain to be deleted. This should be the name of the domain you are currently
logged into, displayed in the Virtual Connect Domain Name box on the Domain Settings

(Configuration) screen (on page

22

).

5.

Click OK.

If deleting a domain that was using MAC addresses predefined by HP, the administrator should also update
the "Teaming" driver configuration file on the host OS. Otherwise, the driver reinitializes to the saved MAC

address predefined by HP and not the factory default value.
When a VCM domain is deleted, VCM resets VC 8Gb 24-Port FC Modules to a factory default condition.

This operation can take up to 50 seconds per VC 8Gb 24-Port FC Module.

Domain Settings (IP Address) screen

Use this screen to set a domain IP address for the Virtual Connect domain. This IP address is then consistent,

regardless of which module is primary within the domain.
The optional domain IP address setting allows for a consistent IP address that is independent of the

interconnect module on which it is running. If set, this IP address must be unique within the network and must

be different than the IP address of the module itself. If this IP address is not set, the VC Manager can still be

reached through the IP address of the host VC-Enet module.
To use an optional domain IP address, select the Use Domain IP address checkbox, and then enter the IP

Address, Subnet Mask, and Default Gateway.

NOTE:

Even if a domain IP address is provided, the normal IP address assigned to the

interconnect bay can still be used.