beautypg.com

Capacitance measurement, Gdm-834x series user manual, Set to diode measurement 1. press the – GW Instek GDM-8300 series User Manual User Manual

Page 46

background image

GDM-834X Series User Manual

46

Capacitance Measurement

The capacitance measurement function checks the capacitance of a
component.

Set to Diode
Measurement

1. Press the

/

key twice to activate

capacitance measurement.
Note: pressing the

/

key once will activate

the diode measurement instead.

2. The mode will switch to capacitance mode

immediately, as shown below.

Display

Capacitance

indicator

Capacitance

units

Measurement

range

S

n F

Connection

Connect the test lead between the VΩ

terminal and COM terminal; Positive-V,
Negative-COM. The display updates the
reading.

CAT 600V

COM

250V

W

V

T0.5A

FUSE

INPUT

MAX

500Vpk

12A

MAX

750V

1000V

MAX

0.5A

MAX