beautypg.com

GW Instek GDM-8300 series User Manual User Manual

Page 125

background image

COMMAND OVERVIEW

125

MEASure:CONTinuity?

Returns the continuity measurement on the first display.
Example: MEAS:CONT?
Returns the continuity.

MEASure:DIODe?

Returns the diode measurement on the first display.
Example: MEAS:DIOD?
Returns the diode measurement.

MEASure:TEMPerature:TCOuple?

Returns the temperature for the selected thermocouple type on
the first display.
Parameter:[NONE] | J | K | T
Example: MEAS:TEMP:TCO? J
> +2.50E+1
Returns the temperature.

MEASure2:VOLTage:DC?

Returns the DC voltage measurement on the second display.
Parameter: [None] | [Range( | MIN | MAX | DEF)]
Example: MEAS2:VOLT:DC?
>+0.488E-4
Returns the DC voltage measurement as 0.0488 mV.

MEASure2:VOLTage:AC?

Returns the AC voltage measurement on the second display.
Parameter: [None] | [Range( | MIN | MAX | DEF)]
Example: MEAS2:VOLT:AC?
>+0.511E-3
Returns the AC voltage measurement as 0.511 mV.