Point staking summary – Spectra Precision Survey Pro v3.80 Recon iPAQ User Manual User Manual
Page 89
Fieldwork
81
d.
The rod man needs to move back by 0.2 feet to
be over the design point. Rather than take
another shot, we will instruct him to use a tape
and place a stake at that location. Tap the
6WRUH7DSH« button to store the point.
e.
Enter the following data in the Store Point
(Tape Offset) Dialog Box:
Point Name
:
6
Description
:
Staked
Tape Out/Tape In (+/-)
:
0.2
and tap
6WRUH. This
will result in coordinates for the stored point
that are 0.2 feet further from the total station
than the last shot to the prism.
Note: Negative
Tape Out/Tape In
values are toward the
total station and positive values are away from the
total station.
Point Staking Summary
1.
Open a job that contains the design points that you want to stake.
2.
Check the job settings.
3.
Setup a backsight.
4.
Stake the points from the Stake Points screen.