Screen Examples
139
Once the total station is aiming near the prism, the
6HDUFK button is
used to start the total station in a search pattern. The search pattern
continues until it finds the prism.
The
/RFN button puts the total station in track mode where it will
track the movements of the prism and
6WRS will stop the total
station from tracking the prism.
Taking a Shot in Remote Mode
When running in a non-remote mode, tapping the
7UDYHUVH or 6LGH 6KRW button will simply trigger the
total station to take a shot. When running in remote
mode, tapping these buttons will open the Remote Shot
screen.
The Remote Shot screen is identical to the Remote
Control screen except it has an additional button that
allows you to trigger the total station to take a shot.
The screen is used to properly align the total station
with the prism prior to taking a shot. Once the total
station is aligned, a shot is taken by tapping the
7DNH 6KRW button.
If the Remote Shot screen was accessed by performing
a side shot, you will return to the Remote Shot screen
after the shot is completed. If the Remote Shot screen
was accessed by performing a traverse shot, you will return to the
Traverse / Sideshot screen after the shot is completed.