Fieldwork
71
b.
Tap
,QVHUW« and
enter a new point
using the
General
and
Location
cards with the
following values, as
shown:
Point Name
:
2
Northing
:
5050
Easting
:
5050
Elevation
:
100
Description
:
Backsight
and then tap OK.
4.
Set up your backsight. In this example, we will
setup on Point 1 and backsight Point 2, which was
just created.
a.
Access the
6XUYH\ , %DFNVLJKW 6HWXS screen.
b.
In the
Occupy
Point
field, enter
1
as the point
name.
Tip: You can also select an existing point from a map
view or from a list by using the
power button.
c.
Enter an
HI
and
HR
of
5
feet each.
d.
Toggle the
%6 'LUHFWLRQ
/
%6 3RLQW
button to
%6 3RLQW
and enter
2
as the point name.
e.
Leave the
Fixed HR at Backsight
field unchecked.
f.
Confirm that the
Backsight Circle
value is zero. If it displays a
non-zero value, tap the
&LUFOH«
button and set it to zero.