SEED HAWK® 30 SERIES OPERATOR’S MANUAL 

 70 




4.22.7  REMOVE ALL SENSORS 


This menu item is used when installing a previously used monitor on a new system. Selecting 
this  item  will  clear  the  monitor’s  memory  of  all  learned  sensors.  This  selection  cannot  be 
undone.  This  selection  does  not  affect  CAN  based  sensors  (meters  and  down  pressure),  only 
MUX based sensors (ground speed, fan speed, bin level). 

 












4.23   ALARMS 


The alarm display will become active when any conditions fall below or rise above the set alarm 
point. For example: Low Bin level, No Ground Speed, Low or High Fan Speed and Low Meter 
Speed  are  all  alarm  conditions.  All  alarms  operate  in  a  similar  fashion:  An  audible  alarm  will 
sound and an alarm message will appear on the display instructing the user to press the soft 
key labeled F1 to acknowledge the alarm. 
 
Once acknowledged, the audible alarm will cease and an icon of a bell at the top of the display 
will flash. Also, an icon associated with the specific alarm will blink. For example if the bin level 
alarm for bin #1 becomes active and is acknowledged, the Bin 1 icon will flash along with the 
alarm bell icon. If bin 2 then shows an alarm condition then the audible alarm will sound again. 
Once acknowledged, the bin 1 and bin 2 icons will flash along with the alarm bell icon. 
 
Low and High fan speed alarms can’t be acknowledged. The alarm condition must be corrected 
to clear the screen of the alarm warning and to quiet the audible alarm. If this alarm is going off 
in  error,  check  the  high  and  low  alarm  point  settings  by  going  to  the  sensor  configuration 
menu, highlighting the sensor in question and pressing the “Settings” soft key. 







FIGURE 4.79