2. ACON-C/CG,
PCON-C/CG
68
(30) Stop Mode Selection (ASO1, ASO0) PLC Output Signal
Select the stop mode for the duration before the movement to the next position after a positioning is
completed.
If the duration for a stop is long, the system automatically turns the servo OFF to reduce the power
consumption.
Refer to the operation manual for the controller for more information.
ASO1 ASO0
Function
Reference
OFF OFF
Disabled
(Set
in
delivery)
OFF ON
Automatic Servo OFF Method
Parameter No. 36 is valid for T
ON OFF
Automatic Servo OFF Method
Parameter No. 37 is valid for T
ON ON
Automatic Servo OFF Method
Parameter No. 38 is valid for T
T :
T
Movement
Command
Actuator
Moving
Target Position
Servo
Condition
In automatic servo OFF duration
(Green LED blinks)
Servo ON
Condition
Waiting time (sec) before servo is
turned OFF after the positioning is completed
.