IAI America PCON-CFA User Manual
Page 113
3. SCON-CA/CF
A
107
(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)
Signal Type
Bit
Symbol
Contents
Details
Pressing
Current
Limit
Value
16-bit
data
-
16-bit integer
Specify the current-limiting value to be used during push-motion
operation.
The allowable specification range is 0 (0%) to 255 (100%).
The actual settable range varies depending on each actuator.(Refer
to the catalog or Operation Manual for the actuator.) If a move
command is issued by specifying a value exceeding the maximum
push-motion current, an alarm will occur.
3.8 (2)
b15
BKRL Forced brake release: When it is turned ON, the brake is released.
3.6.7 (18)
b14 RMOD
Operating mode selector: The AUTO mode is selected when this
signal is OFF, and the MANU mode is selected when the signal is
ON.
3.6.7 (19)
b13 DIR
Push direction specification:
“OFF” for the direction reducing the positioning band from the target
position,
“ON” for the direction adding the positioning band to the target
position
3.6.7 (22)
b12 PUSH
Push-motion specification: Positioning operation is performed when
this signal is OFF, and push-motion operation is performed when the
signal is ON.
3.6.7 (21)
b11
b10
b9
-
Unavailable -
b8
JOG+ + Jog: “ON” for Movement in the Opposite Direction of Home
3.6.7 (13)
b7
JOG-
-Jog: “ON” for Movement to the Home Direction
3.6.7 (13)
b6 JVEL
Jog-speed/inch-distance switching:
The values set in parameter No. 26, “Jog speed” and parameter No.
48, “Inch distance” are used when this signal is OFF, and the values
set in parameter No. 47, “Jog speed 2” and parameter No. 49, “Inch
distance 2” are used when the signal is ON.
3.6.7 (14)
b5 JISL
Jog/inch switching:
Jog operation is performed when this signal is OFF, and inch
operation is performed when the signal is ON.
3.6.7 (15)
b4
SON
Servo ON Command: The servo turns ON when this signal turns ON.
3.6.7 (5)
b3
RES
Reset: A reset is performed when this signal turns ON.
3.6.7 (4)
b2
STP
Pause: A pause command is issued when this signal turns ON.
3.6.7 (11)
b1 HOME
Home return: A home-return command is issued when this signal
turns ON.
3.6.7 (6)
PLC Output
Control
Signal
b0 DSTR
Positioning Command: A move command is issued when this signal
turns ON.
3.6.7 (8)