IAI America PCON-CFA User Manual
Page 265
6. Appendix
259
[5] A search for EtherCAT(R) slaves on the network will be executed, and the list of the slaves found will
be displayed.
Find the field where the node address* with the ACON, PCON or SCON-CA setting in the list
displayed.
Check to make sure that the format (RC-ECT-FMODx) displayed in “Detected network configuration”
and “Automatic network setup result” are the same. Upon checking, select OK.
* x represents the setting of parameter No. 84 Field Bus Operation Mode. [Refer to 2.5.1, 3.5.1 or
4.5.1, "Operation Mode Selection."]
[6] Select OK to transfer the setup result to the PLC.
[7] When the transfer is completed, the following screen will appear. Select OK.
[8] Lastly, a confirmation message will appear. Select OK.
Check to make sure that the RUN LED of ACON, PCON or SCON-CA is lit, and ERR LED is not lit.
This completes the automatic setup.