Page 263

6. Appendix
257
6. Appendix
6.1 Setup of Connection with Omron’s Master Unit
The following devices and software are required to connect to an Omron master.
[1] PLC CPU unit:
(Ex) CJ1G-CPU43H
[2] EtherCAT(R) master unit (Position control unit):
(Ex) NC-882
[3] Setting software:
CX-One V4.0 or later CX-Programmer V9.11 or later
[4] IAI controller designed for EtherCAT(R)
6.2 Automatic Network Setup
The setup procedure is as follows:
[1]
Open CX-Programmer. Double-click I/O Table/Unit setting listed on the project tree, and open the I/O
table.
[2] Double-click the field for CJ1W-NC882 position control unit (EtherCAT(R) communication type) on the
CPU rack tree and launch the position control unit setting tool (hereinafter referred to as the "NCF
tool").