IAI America PCON-CFA User Manual
Page 199
4. SCON-CA
193
(* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the applicable bit is “0.”)
Address Bit
Symbol
Function
Details
Acceleration
16-bit
data
-
Deceleration
16-bit
data
-
16-bit integer.
Specify the acceleration and deceleration at which to move the
actuator.
The unit is 0.01 G, while the specifiable range is 1 to 300.
(Example) To set 0.30 G, specify “30.”
If a move command is issued by specifying “0” or a value
exceeding the maximum acceleration or maximum
deceleration, an alarm will occur.
4.8 (3)
Load current
threshold
16-bit
data
-
16-bit integer.
If judgment will be made as to whether or not the load current
exceeded the set value, specify the threshold value for current
using this register.
The specifiable range is 0 (0%) to 510 (200%).
If judgment is not performed, enter “0.”
4.8 (3)
b15
b14
-
Cannot be used.
-
b13 NTC1
Vibration damping
control mode
selection 1
b12 NTC0
Vibration damping
control mode
selection 0
Select the vibration damping control
parameter set to be used.
NTC1 NTC0
Function
OFF OFF
Do not use vibration
damping control.
OFF
ON
Select parameter set 1.
ON
OFF
Select parameter set 2.
ON
ON
Select parameter set 3.
4.6.11 (29)
b11
b10
-
Cannot be used.
-
b9
ASO1
Stop mode 1
b8
ASO0
Stop mode 0
Select the stop mode during standby.
ASO1 ASO0
Function
OFF OFF
Invalid (The servo is
always on.)
OFF ON
The servo turns off after
the time is set in
parameter No. 36.
ON OFF
The servo turns off after
the time is set in
parameter No. 37.
ON ON
The servo turns off after
the time is set in
parameter No. 38.
4.6.11 (31)
b7 MOD1
b6 MOD0
Acceleration/deceleration mode:
Trapezoid pattern when both signals are OFF, S-motion when
MOD1 is OFF and MOD0 is ON, or primary delay filter when
MOD1 is ON and MOD0 is OFF.
4.6.11 (30)
b5 GSL1
Servo gain
parameter set
selection 1
PLC output
Control
signal 1
b4 GSL0
Servo gain
parameter set
selection 0
Select the servo gain parameter set to be
used.
GSL1
GSL0
Function
OFF
OFF
Select parameter set 0.
OFF
ON
Select parameter set 1.
ON
OFF
Select parameter set 2.
ON
ON
Select parameter set 3.
4.6.11 (33)