(29) Acceleration/deceleration mode (MOD1
MOD0)
PLC output signal
Dedicated ACON function
This signal is used to select the acceleration/deceleration pattern characteristics. Select one of them before
the actuator movement command.
MOD1 MOD0
Pattern
name
Remarks
OFF
OFF
Trapezoid Pattern
Factory setting
OFF ON
S-shaped
Motion
ON
OFF
First-Order Lag Filter
ON ON
Unavailable
Trapezoid Pattern
*The Acceleration and Deceleration are set in the “Acceleration” and “Deceleration” data boxes on the position
data.
S-shaped Motion
When the value in the “Acceleration/deceleration mode” field in the position table is set to 1 (S-shaped
motion), the S-shaped motion degree is defined by parameter No. 56.
The setting unit is % and the setting range is from “0" to “100.”
This is set to 0% (S-shaped motion disabled) in the factory setting.
An S-shaped motion becomes a sine waveform after one cycle of the acceleration time.
Specify the degree of amplitude by parameter No. 56.
Parameter No. 56 setting [%]
Degree of amplitude
[Factory setting]
S-shaped motion disabled (Dotted line in the figure below)
100
Sine waveform amplitude x 1 (Chain double-dashed line in the figure below)
50
Sine waveform amplitude x 0.5 (Chain line in the figure below)
10
Sine waveform amplitude x 0.1 (Solid line in the figure below)
Velocity
Acceleration
Deceleration
Time
Setting: 50
Setting: 100
Setting: 10
Acceleration time
Time
Amplitude
Velocity