4. SCON-CA

214

(1)

PLC address configuration (* “n” shows the node address of each axis.)

Parameter

No. 84

SCON-CA side

DI and input register

PLC side output

address (bytes)

SCON-CA side

DO and output register

PLC side input

address (bytes)

Port number 0 to 15

n+0, n+1

Port number 0 to 15

n+0, n+1

n+2, n+3

Occupied area

n+2, n+3

n+4, n+5

n+4, n+5

n+6, n+7

Current position

n+6, n+7

n+8, n+9

n+8, n+9

7

Occupied area

n+10, n+11

Force feedback data

n+10, n+11

(Note) The areas denoted by Occupied area cannot be used for any other purpose.

Also, exercise caution to avoid node address duplication.

(2) I/O Signal Allocation for each Axis

The I/O signals of each axis consist of one input word (6 words = 12 bytes) and one output word in the I/O
areas.

z The areas controlled by port number are controlled using ON/OFF bit signals.

z The current position is a 2-word (32-bit) binary data (unit: 0.01 mm).

z The force feedback data is a 2-word (32-bit) binary data (unit: 0.01N).

PLC

output

Address

(* “n” shows the node address of each axis.)

Controller

input port

number

1 word (1CH) = 16 bits


1 word = 2 bytes =16 bits

n+0, n+1