beautypg.com

IAI America PCON-CFA User Manual

Page 123

background image

3. SCON-CA/CF

A

117

(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)

Address Bit

Symbol

Function

Details

b2 DIR

Push direction specification:
“OFF” for the direction reducing the positioning band from the
target position
“ON” for the direction adding the positioning band to the target
position

3.6.7 (22)

b1 PUSH

Push-motion specification :
Positioning operation is performed when this signal is OFF, and
push-motion operation is performed when the signal is ON.

3.6.7 (21)

Control

Signal 1

b0 -

Unavailable

-

b15

BKRL

Forced brake release: When it is turned ON, the brake is released

3.6.7 (18)

b14 RMOD

Operating mode selector:
The AUTO mode is selected when this signal is OFF, and the
MANU mode is selected when the signal is ON.

3.6.7 (19)

b13

b12

b11

b10

b9

- Unavailable

-

b8

JOG+

+Jog: “ON” for Movement in the Opposite Direction of Home

3.6.7 (13)

b7

JOG-

-Jog: “ON” for Movement to the Home Direction

3.7.7 (13)

b6 JVEL

Jog-speed/inch-distance switching:
The values set in parameter No. 26, “Jog speed” and parameter
No. 48, “Inch distance” are used when this signal is OFF, and the
values set in parameter No. 47, “Jog speed 2” and parameter No.
49, “Inch distance 2” are used when the signal is ON.

3.6.7 (14)

b5 JISL

Jog/inch switching:
Jog operation is performed when this signal is OFF, and inch
operation is performed when the signal is ON.

3.6.7 (15)

b4 SON

Servo ON Command: The servo turns ON when this signal turns
ON.

3.6.7 (5)

b3

RES

Reset: A reset is performed when this signal turns ON.

3.6.7 (4)

b2

STP

Pause: A pause command is issued when this signal turns ON.

3.6.7 (11)

b1 HOME

Home return: A home-return command is issued when this signal
turns ON.

3.6.7 (6)

PLC Output

Control

Signal 2

b0 DSTR

Positioning Start:
A move command is issued when this signal turns ON.

3.6.7 (8)

This manual is related to the following products: