Acon, 3) i/o signal assignment, Acon-c/cg, pcon-c/cg 23 – IAI America PCON-CFA User Manual
Page 29
2. ACON-C/CG,
PCON-C/CG
23
(3)
I/O signal assignment
The controller's I/O port signal varies depending on the parameter No. 25 setting.
(Refer to Operation Manual for the controller main body for more information.)
ACON
Parameter No. 25 setting
Positioning mode
Teaching mode
256-point mode
0 1 2
Category
Port No.
Symbol
Signal Name
Symbol
Signal Name
Symbol
Signal Name
0 PC1
PC1
PC1
1 PC2
PC2
PC2
2 PC4
PC4
PC4
3 PC8
PC8
PC8
4 PC16
PC16
PC16
5 PC32
Command position No.
PC32
Command position No.
PC32
6
-
MODE
Teaching Mode Command
PC64
7 -
JISL Jog/inching
selector
PC128
Command position No.
8 -
Unavailable
JOG+ +Jog
-
Unavailable
9
BKRL
Forced brake release
JOG-
-Jog
BKRL
Forced brake release
10
RMOD
Operating mode selector
RMOD
Operating mode selector
RMOD
Operating mode selector
11
HOME
Home return
HOME
Home return
HOME
Home return
12 *STP
Pause
*STP
Pause
*STP
Pause
13 CSTR
Positioning
Start
CSTR/
PWRT
Positioning Start/ Position
Data Import Command
CSTR Positioning
Start
14 RES
Reset
RES
Reset
RES
Reset
PLC Output
ĺ
ACON Input
15
SON
Servo ON Command
SON
Servo ON Command
SON
Servo ON Command
0 PM1
PM1
PM1
1 PM2
PM2
PM2
2 PM4
PM4
PM4
3 PM8
PM8
PM8
4 PM16
PM16
PM16
5 PM32
Completed Position No.
PM32
Completed Position No.
PM32
6
MOVE Moving
Signal MOVE Moving
Signal PM64
7
ZONE1
Zone 1
MODES
Teaching mode Signal
PM128
Completed Position No.
8
PZONE
Position zone
PZONE
Position zone
PZONE
Position zone
9
RMDS
Operation Mode Status
RMDS
Operation Mode Status
RMDS
Operation Mode Status
10
HEND
Home return completion
HEND
Home return completion
HEND
Home return completion
11 PEND
Positioning completion
signal
PEND/
WEND
Positioning completion signal/
position-data read complete
PEND
Positioning completion signal
12
SV
Operation preparation end
SV
Operation preparation end
SV
Operation preparation end
13
*EMGS
Emergency stop
*EMGS
Emergency stop
*EMGS
Emergency stop
14 *ALM
Alarm
*ALM
Alarm
*ALM
Alarm
ACON Output
ĺ
PLC Input
15
Unavailable
-
Unavailable
-
Unavailable
The symbol with a * mark shows the ON signal in normal condition.