beautypg.com

IAI America PCON-CFA User Manual

Page 100

background image

3. SCON-CA/CF

A

94

(1)

PLC channel configuration (* “n” shows the node address of each axis.)

Parameter

No.84

PCON-CA/CFA side

DI (Port No.)

PLC side output

address (bytes)

PCON-CA/CFA side

DO (Port No.)

PLC side input

address (bytes)

0

0 to 15

n+0, n+1

0 to 15

n+0, n+1

(Note) Be careful of using duplicated node addresses.

(2)

I/O Signal Allocation for each Axis

The I/O signals of each axis consist of one input word (1 word = 2 bytes) and one output word in the I/O
areas.
x This is controlled by ON/OFF bit signals from the PLC.

(* “n” shows the node address of each axis.)

PLC output
Channel

Controller input
port number

1 word (1CH) = 16 bits



(* “n” shows the node address of each axis.)

PLC input
Channel

Controller output
port number

1 word (1CH) = 16 bits





















n+0, n+1

n+0, n+1

1 word = 2 bytes =16 bit

1 word = 2 bytes =16 bit

address

address