2. Specifications
[With double guides]
Restriction in Stroke and Maximum Speed (unit: mm/s)
Type
Motor Type
Lead
(mm)
Stroke (mm)
50
100
150
200
250
300
RCP2-RGD3C
28P
2.5
114<93>
-
-
5
187
-
-
RCP2-RGD4C
42P
2.5
125<114>
118<114>
87
5
250
237
175
10
458
350
RCP2-RGD6C
56P
4
130
8
210
16
450<400>
(Note) Values in brackets < > are the maximum speed when
vertically oriented.
[Splash proof type]
Restriction in Stroke and Maximum Speed (unit: mm/s)
Type
Motor Type
Lead
(mm)
Stroke (mm)
50
100
150
200
250
300
RCP2W-RA4C
42P
2.5
125<115>
115
85
5
190
175
10
450<250>
350<250>
RCP2W-RA6C
56P
4
100
8
200
16
320<265>
RCP2W-RA10C
86P
2.5
63
5
125
10
250<167>
(Note) Values in brackets < > are the maximum speed when
vertically oriented.
Caution: Please do not set the speed or acceleration/deceleration settings beyond the rated values.
It may cause an occurrence of vibration, malfunction, or shorten the product life.
When having the actuator run to synchronize with multiple axes, adjust the speed setting
of the axis with the maximum speed and the acceleration/deceleration of the axis with the
minimum acceleration/deceleration.
Setting especially the acceleration/deceleration beyond the rated values may cause a creep
or a slip of the coupling.