Specifications – IAI America RCP2W-RA10C User Manual
Page 28

22
2. Specifications
2.
Specifications
(1)
Maximum Speed
The maximum speed for the actuator is limited due to the resonance of the ball screw axis and the limitation
of the number of motor rotation.
Make sure that the maximum speed of your actuator does not exceed the applicable limit specified in the
table below.
[Standard]
Restriction in Stroke and Maximum Speed (unit: mm/s)
Type
Motor Type
Lead
(mm)
Stroke (mm)
25
50
75
100
RCP-RA2C
20P
1
25
Restriction in Stroke and Maximum Speed (unit: mm/s)
Type
Motor Type
Lead
(mm)
Stroke (mm)
50
100
150
200
250
300
RCP2-RA3C
28P
2.5
114
-
-
5
187
-
-
RCP2-RA4C
42P
2.5
125<114>
118<114>
87
5
250
237
175
10
458
350
RCP2-RA6C
56P
4
130
8
210
16
450<400>
RCP2-RA8C
60P
5
150
10
300
RCP2-RA10C
86P
2.5
63
5
125
10
250<167>
(Note) Values in brackets < > are the maximum speed when
vertically oriented.