78

Flat Type (F45) - Moments and Loading Capacity


The directions of moments generated around the flat type are shown in the figure below.



















The points of action of Ma and Mb moments are shown in the figure below.










Point of action


If the flat type is used horizontally, make sure the load applied to the end of the plate does not exceed the Ma
moment. Refer to the table below listing the allowable loads at the tip as calculated from the Ma moment at each
stroke.

Stroke

50

100

150

200

250

300

Distance from point of action (m)

0.06 0.11 0.16 0.21 0.26 0.31

N

45.0 24.5 16.9 12.9 10.4 8.7

F45 type

(kgf)

4.59 2.50 1.72 1.31 1.06 0.89












Distance from point of action