Movement after Power On (Standard Type)

Example of use in operation) After the power is turned on, move the actuator to the position 150 mm from the

home at a speed of 200 mm/sec.

Position-data table (Field(s) within thick line must be entered.)

No. Position

Speed

Acceleration/

deceleration

Push Positioning

band

Acceleration

only MAX

0

0 100

0.3 0 0.1 0

1

150

200

0.3 0 0.1 0

RCS controller












































P

L

C

[7] [4]

[3]







[2]

[1]

[10]





[9] [5]

[8]





[11] [6]

PIO

Signal name

Start

Command position 1

Command position 2

Command position 4

Command position 8

Pause

Reset

Servo ON

Completed position 1

Completed position 2

Completed position 4

Completed position 8

Position complete

Home return completion

Zone

Alarm

Emergency stop

Moving

Category

Input

















Output

Reference flow

Power ON

Select/enter command position 1.

[1]

[2]

[3]

[4]


[5]

[6]


[7]



[8]



[9]

[10]

[11]

Start input ON

Home return starts.

Position complete output OFF

Moving output ON

Start input OFF

Home return completes.

Home return completion output ON

Movement to position 1 starts.

Position complete output turns ON 0.1 mm
before position 1.

Completed position 1 is output.

Moving output OFF

Movement to position 1 completes.

With the absolute specification, the home
return completion signal will turn ON after
the power is turned on, and the actuator will
move directly to position 1 without
performing home return.

Servo ON input ON

Pause input ON