beautypg.com

IAI America RCS-E User Manual

Page 72

background image

56
























T1:

5 msec or more; time after selecting/entering a command position until the start input turns ON

(The scan time of the host controller must be considered.)


Data of 0 distance from the home need not be always entered in position 0.
In this example, data of 0 distance from the home was entered in position 0. Of course, such data can also be
entered in any other position of 1 to 15.



Note: When the start signal turns ON, the position complete output will turn OFF and the moving

output will turn ON.

The start signal must be turned OFF with the confirmation that the moving output has turned
ON while the start signal remains ON.

If the start input remains ON as shown below, the position complete output will not turn ON even
when the actuator movement is completed. The moving output will not turn OFF, either.











Command position


Start

Position complete

Completed position


Moving





Actuator movement

Note

Speed

Turn all of command positions
1, 2, 4 and 8 OFF.

Completed positions 1,
2, 4 and 8 all turn OFF.

Start

Position complete

Moving


Actuator

1 msec or less

Position 0