Data entry Page 44
Page 44
28
3. Data Entry
This controller doesn’t use command words, so there is no need to create a program.
All you need is to enter position data in the position-data table, and the actuator will move to the specified
position.
Position data consists of number (No.), position (Position), speed (Speed), acceleration/deceleration (ACC), push
(Push), positioning band (Pos. band), and acceleration only MAX (ACC MAX). The description in parentheses is
as displayed on the teaching pendant.
Position data can be specified in two different modes: by absolute coordinate specification (absolute mode) in
which the distance from the home is entered, or by relative coordinate specification (incremental mode) in which
the incremental movement from the current position is entered.
Position-data table
No.
Position Note
Speed
Acceleration/
deceleration
Push
Positioning
band
Acceleration
only MAX
0
0 100
0.3 0 0.1 0
1
30 100
0.3 0 0.1 0
2
10 100
0.3 0 0.1 0
15
100
100
0.3
0
0.1
0
When data is entered in the position column of the position-data table, the default values will be automatically
entered in the remaining columns. Change the default values as necessary.
To change a default value, change the corresponding parameters starting with “Default.”
The default values vary depending on the actuator type.
This indicates that the incremental mode is active. (This symbol is displayed only on the teaching pendant.
Separate columns for incremental specification are provided in the PC software.)
Note: Enter position data first. Any attempt to enter other data before position data will be rejected.
You can enter position data containing two decimal places.
However, the controller only recognizes position data as a multiple of its minimum resolution.
The minimum resolution of the controller varies depending on the actuator lead.
For the above reason, the second decimal place in the entered position data may be rewritten in
accordance with the actuator lead.
Example: Entered value
Stored value
50.01
50.03
~
~
~
~
=