13

Piano switches 1 to 4 --- Address switches

Use these switches to set the address of the applicable actuator if two or more axes are connected to the
SIO connector. A desired address between 0 to 15 can be set.
(The factory setting is OFF for all of switch Nos. 1 to 4. This setting represents a condition where only one
axis is used.)
Use these switches to set a desired address for each controller. Make sure no address is duplicated among
the controllers. As long as they are unique, the addresses may not be contiguous and missing numbers are
allowed.

Piano switch numbers

Address

1 2 3 4

0 OFF OFF OFF OFF
1 ON OFF OFF OFF
2 OFF ON OFF

OFF

3 ON ON

OFF

OFF

4 OFF

OFF ON OFF

5 ON OFF ON OFF
6 OFF ON ON OFF
7 ON ON ON OFF
8 OFF OFF OFF ON
9 ON

OFF

OFF

ON

10 OFF ON OFF ON

11 ON ON OFF ON

12 OFF OFF ON ON
13 ON OFF ON ON
14 OFF ON ON ON
15 ON ON ON ON
















Piano switche 5 ABS-CLR (absolute specification)

(Second from the top)
This switch clears the data of the absolute encoder. Use it to perform an absolute reset. Normally this switch

should be in the OFF position.

Piano switche 6

(First from the top)
Write protect switch. This switch is used for remote update.

 Normally this switch should be in the OFF position.

The controller link cable is 200 mm
long.
A maximum of 16 controllers can