IAI America RCS-E User Manual
Page 66
50
Position-data table (Field(s) within thick line must be entered.)
No. Position
Speed
Acceleration/
deceleration
Push Positioning
band
Acceleration
only MAX
0
* * * * * *
1
150
200
0.1 0 0.1 1
T1:
5 msec or more; time after selecting/entering a command position until the start input turns ON
(The scan time of the host controller must be considered.)
Note: When the start signal turns ON, the position complete output will turn OFF and the moving
output will turn ON.
The start signal must be turned OFF with the confirmation that the moving output has turned
ON while the start signal remains ON.
If the start input remains ON as shown below, the position complete output will not turn ON even
when the actuator movement is completed. The moving output will not turn OFF, either.
Speed
Position 1
Position 1
Command position
Start
Position complete
Completed position
Moving
Actuator movement
Positioning band
Start
Position complete
Moving
Actuator
1 msec or less