beautypg.com

IAI America RCS-E User Manual

Page 66

background image

50


Position-data table (Field(s) within thick line must be entered.)

No. Position

Speed

Acceleration/

deceleration

Push Positioning

band

Acceleration

only MAX

0

* * * * * *

1

150

200

0.1 0 0.1 1

























T1:

5 msec or more; time after selecting/entering a command position until the start input turns ON

(The scan time of the host controller must be considered.)



Note: When the start signal turns ON, the position complete output will turn OFF and the moving

output will turn ON.

The start signal must be turned OFF with the confirmation that the moving output has turned
ON while the start signal remains ON.

If the start input remains ON as shown below, the position complete output will not turn ON even
when the actuator movement is completed. The moving output will not turn OFF, either.











Speed

Position 1

Position 1

Command position

Start

Position complete


Completed position

Moving





Actuator movement

Positioning band

Start

Position complete

Moving


Actuator

1 msec or less