IAI America RCS-E User Manual
Page 76
60
Example)
If the start signal for movement to position 2 is input while the actuator is moving to position 1 in
the push & hold mode, the actuator will move to the position 10 mm from where it was when the
input signal was input.
No. Position
Speed
0 *
*
1 50 100
2
10 100
(3) Cumulative errors due to repeated incremental moves
Position data is recognized only as a multiple of the minimum resolution. The minimum resolution is
determined by the lead and the number of encoder pulses. Therefore, a margin of error may occur between
the entered position value and the actual movement of the actuator. If an incremental move is repeated, this
error will accumulate.
The maximum error range for each actuator type is shown below:
Type
Motor
(W)
Speed
type
Screw
lead (mm)
Maximum
error (
)
Type
Motor
(W)
Speed
type
Screw
lead (mm)
Maximum
error (
)
L 2.5 0.2
L 2.5 0.3
M 5 0.3
M 5 0.6
SA4 20
H 10 0.6
RA35 20
H 10 1.2
L 3 0.2
L 2.5 0.2
M 6 0.4
M 5 0.3
SA5 20
H 12 0.7
RA45 30
H 10 0.6
L 3 0.2
M 5 1.6
M 6 0.4
Rod
type
RB7525
60
H 10 3.3
Slider
type
SA6 30
H 12 0.7
L 2.5 0.2
M 5 0.3
Flat
type
F45 30
H 10 0.6
=
Distance
10 mm
Command position
Start
Position complete
Completed position
Actuator movement
Speed
Position 1
Position 2
Position 2