46


Position-data table (Field(s) within thick line must be entered.)

No. Position

Speed

Acceleration/

deceleration

Push Positioning

band

Acceleration

only MAX

0

* * * * * *

1 280

200

0.3

50

15

0

2

40 100

0.3 0 0.1 0




















T1:

5 msec or more; time after selecting/entering a command position until the start input turns ON

(The scan time of the host controller must be considered.)

Each command position must be input after the position complete output has turned ON for the movement to the
previous position.

Note: When the start signal turns ON, the position complete output will turn OFF and the moving

output will turn ON.

The start signal must be turned OFF with the confirmation that the moving output has turned
ON while the start signal remains ON.

If the actuator has missed the load, the position complete output will not turn ON as shown
below. The completed position will be output and the moving output will turn OFF.















Command position


Start

Position complete

Moving

Completed position

Actuator movement

Speed

Position 1

Position 2

Position 1

Note Note

Note

Position 1

Position 2

Position 1

Command position

Start

Position complete

Moving

Completed position

Actuator movement

Speed

Position 1

Position 2

Position 1

Position 1

Position 2

Position 1