beautypg.com

IAI America RCS-E User Manual

Page 47

background image

31

Acceleration/deceleration

set in (4)

Acceleration/deceleration
set in (4)

Maximum acceleration
according to the load

S

peed

S

peed

Moving distance

Moving distance



(7) Acceleration only MAX

(ACC MAX)

 Select the specified acceleration or maximum acceleration by entering

“0” or “1.”
The default value is “0.”
0: Specified acceleration --- The value entered in (4) becomes the

actual acceleration/deceleration.

1: Maximum acceleration --- The maximum acceleration set according

to the load is used.
The deceleration conforms to the value
entered in (4).


(7) Acceleration only MAX = 0

(7) Acceleration only MAX = 1









Caution:

As a rough guide, enable the acceleration only MAX setting when the actual payload is no more than
one-third of the rated loading capacity.
Check the rated loading capacity of your actuator by referring to the supplied specification list of
supported actuators.