Specification, 1 base specifications, Base specifications – IAI America RCS-E User Manual
Page 25
9
2. Specification
2.1 Base
Specifications
Item Specification
Supply voltage
24 VDC
10%
Type
RA35
RA45, F45
RB75 (60 W)
SA4, SA5
SA6
Supply current [A]
Rating Peak
1.8
4.3
2.4 6.0 3.9 7.5 1.2 3.7 1.4 3.9
Maximum motor output
60 W (Torque limit x 2) / Other (x 3)
Surrounding air
temperature/humidity
0 to 40
C, 85%RH or less
Surrrounding environment
IP10, free from corrosive gases
Weight 540
g
Protective functions
Regenerative voltage error, motor overcurrent, power-stage overheat,
encoder error, motor overload, overspeed
LED indicators
RDY (green), RUN (green), ALM (red), ENC (orange)
DI/DO interface
24 VDC, isolated
8 dedicated
input ports
Start
Command position number (4-bit binary)
* Pause
Reset
Servo-ON
Completed position number (4-bit binary)
Position complete
Home return completion
Zone
* Alarm
* Emergency stop
Moving
Input/output
10 dedicated
output ports
Serial interface input/output
Number of positions
16
Data entry method
Teaching pendant, PC software
Storage device
EEPROM 8 kbytes, S-RAM 128 kbytes
Note: Supplying the power-supply port or any I/O port with a voltage beyond the specified level may
result in controller failure.
* indicates a b-contact signal.