50

Command and Response Table for SIS Commands

Symbol definitions for command and response table

]

= CR/LF (carriage return/line feed)

}

= Carriage return (no line feed)

|

= Pipe (can be used interchangeably with the

}

character)

= Space (hard) character

E

= Escape key (hex 1B)

W = Can be used interchangeable with the

E

character

X!

= Input number (for tie)

00 – 16, 20, 32, or 36 (the highest numbered input for your model) (00 = untied)

X@

= Output

01 – 16, 20, 32, or 36 (the highest numbered output for your model)

X#

= Mute, front panel lock

0 = not muted/not locked, 1 = muted/locked

X$

= DDC value (EDID) (see the table on

page 52

)

X%

= Input number

01 – 16, 20, 32, or 36 (the highest numbered input for your model)

X^

= Global preset number

00 through 32 (00 = current configuration)

X&

= Room number (for room presets)

01 through 10 (each can have up to 10 room presets [

X(

s] assigned)

NOTE: A room is a subset of operator selected outputs that relate to each other. The DMS matrix switcher supports up to 10 rooms, each

of which can consist of from 1 to 16 outputs.

X*

= Name

Up to 12 characters for input and output names, global preset names, and room
preset names
11 characters maximum for room names
Upper-and lower-case alphanumeric characters are valid

NOTE: The following characters are invalid or not recommended in the name: ~ , @ = ‘ [ ] { } < > “ : | \ and ?.

X(

= Room preset number

01 through 10

NOTE: A room preset is a stored configuration with all of the outputs assigned to a single room. When a room preset is recalled from

memory, it becomes the current configuration.

X1)

= Connection status

0 = no input connected

1 = input connected

X1!

= Group number (for I/O grouping)

1 through 4 (or 0 = no group)

X1@

= Number (quantity) of inputs

4, 8, 12, 16, 20, 24, 28, 32, 36

X1#

= Number (quantity) of outputs

4, 8, 12, 16, 20, 24, 28, 32, 36

X1$

= Board installed

X0 = No board installed
C1 = DVI 4 inputs x 4 outputs

D1 = Fiber 4 inputs x 4 outputs

C2 = DVI 4 inputs x 0 outputs

D2 = Fiber 4 inputs x 0 outputs

C3 = DVI 0 inputs x 4 outputs

D3 = Fiber 0 inputs x 4 outputs

X1%

= Part number

60-nnnn-01

X1^

= Firmware version number to second decimal place (x.xx)

X1&

= Verbose firmware version-description-

See the

Query controller firmware version (verbose)

command on page 56

upload date/time

X1*

= Voltage

Positive or negative voltage and magnitude

X1(

= Temperature

Degrees Fahrenheit

X2)

= Fan speed

In revolutions per minute (RPM)

X2!

= Power supply status

0 = not installed or failed

1 = installed and OK