Ethernet connection, Ethernet link, Default ip address – Extron Electronics DMS 1600_2000_3200_3600 User Guide User Manual
Page 114: Ethernet connection default ip address, Figure 73. rj-45 connector pinout tables

DMS 1600, DMS 2000, DMS 3200, and DMS 3600 • Ethernet Connection 108
Ethernet Connection
This section provides a high level discussion of the Ethernet connection the switcher and a
primer on the subject of subnetting. Topics that are covered, include:
•
•
Ethernet Link
The rear panel Ethernet connector on the DMS matrix switcher can be connected to an
Ethernet LAN or WAN. This connection makes SIS control of the switcher possible using a
computer connected to the same LAN.
Ethernet Connection
The Ethernet cable can be terminated as a straight-through cable or a crossover cable and
must be properly terminated for your application (see figure 73).
•
Crossover cable — Direct connection between the computer and the
DMS matrix switcher
•
Patch (straight-through) cable — Connection of the DMS matrix switcher to an
Ethernet LAN
A cable that is wired as T568A at one end
and T568B at the other (Tx and Rx pairs
reversed) is a "crossover" cable.
A cable that is wired the same at both ends is
called a "straight-through" cable, because
no pin/pair assignments are swapped.
12345678
RJ-45
Connector
Insert Twisted
Pair Wires
Pins:
Crossover Cable
Straight-through Cable
Pin
1
2
3
4
5
6
7
8
Wire color
White-green
Green
White-orange
Blue
White-blue
Orange
White-brown
Brown
Wire color
T568A
T568B
End 1
End 2
End 1
End 2
White-orange
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
Pin
1
2
3
4
5
6
7
8
Wire color
White-orange
White-green
Blue
White-blue
White-brown
Brown
Wire color
T568B
T568B
White-orange
Orange
Orange
White-green
Blue
White-blue
Green
Green
White-brown
Brown
Figure 73.
RJ-45 Connector Pinout Tables
Default IP Address
To access the DMS matrix switcher via the LAN port, you need the IP address of the
switcher. If the address has been changed to an address comprised of words and
characters, you can determine the actual numeric IP address using the ping utility. If the
address has not been changed, the factory-specified default is 192.168.254.254.
Ping can also be used to test the Ethernet link to the DMS matrix switcher.