DMS 1600, DMS 2000, DMS 3200, and DMS 3600 • Programming Guide

47

Ethernet (LAN) Port

The Ethernet cable can be terminated as a straight-through cable or a crossover cable and
must be properly terminated for your application (see

Ethernet Port

on page 11).

Crossover cable — Direct connection between the computer and the DMS matrix
switcher.

Patch (straight-through) cable — Connection of the DMS matrix switcher to an
Ethernet LAN.

Default IP addresses

To access the DMS matrix switcher via the LAN port, you need the IP address for the unit,
and may need the subnet mask and the gateway address. If the IP address has been
changed to an address comprised of words and characters, you can determine the actual
numeric IP address using the ping (ICMP) utility (see

Ethernet Link

on page 108 for more

details). If the addresses have not been changed, the factory-specified defaults are:

IP address 192.168.254.254

Subnet mask 255.255.0.0

Gateway address 0.0.0.0

Establishing a Connection

Establish a network connection to a DMS matrix switcher as follows:

1.

Open a TCP socket using the IP address of the switcher.

NOTE: If the local system administrators have not changed the value, the factory-

specified default, 192.168.254.254, is the correct value for this field.

The switcher responds with a copyright message including the date, the name of the
product, firmware version, part number, and the current date/time.

NOTE: If the switcher is not password-protected, the device is ready to accept SIS

commands immediately after it sends the copyright message.
If the switcher is password-protected, a

Password

prompt appears below the

copyright message.

2.

If the switcher is password protected, enter the appropriate administrator or user
password.

If the password is accepted, the switcher responds with Login User or Login
Administrator.

If the password is not accepted, the Password prompt reappears.

Connection Timeouts

The Ethernet link times out after a designated period of time of no communications. By
default, this timeout value is set to 5 minutes but the value can be changed (see the

Configure port timeout

SIS commands on page 60).

NOTE: Extron recommends leaving the default timeout at 5 minutes and periodically

issuing the Query (Q) command to keep the connection active. If there are long
idle periods, Extron recommends disconnecting the socket and reopening the
connection when another command must be sent.