Performing soft system resets (modes 3, 4, and 5), Performing soft system resets, Modes 3, 4, and 5) – Extron Electronics DMS 1600_2000_3200_3600 User Guide User Manual
Page 44: Figure 26. soft system resets

DMS 1600, DMS 2000, DMS 3200, and DMS 3600 • Operation
38
Performing Soft System Resets (Modes 3, 4, and 5)
Perform a soft reset of the switcher as follows:
Use an Extron Tweeker or other small screwdriver to press and
hold the rear panel Reset
button until the rear panel Reset LED and the front panel Preset and View buttons blink
once (events reset), twice (IP settings reset), or three times (absolute reset).
Release the Reset button and then
immediately press and release the Reset button again.
Nothing happens if the second momentary press does not occur within 1 second.
RESET
RESET
RESET
CONTROL
ENTER
PRESET
VIEW
ESC
CONTROL
ENTER
PRESET
VIEW
ESC
CONTROL
ENTER
PRESET
VIEW
ESC
Release, then immediately
press and release again.
6 seconds
9 seconds
Press and hold
the Reset button.
3 seconds
View and Esc buttons flash once.
Reset LED flashes once.
Release, then immediately
press and release again.
Reset LED flashes twice.
Press and hold
the Reset button.
Press and hold
the Reset button.
Reset LED flashes
three times.
View and Esc buttons flash twice.
View and Esc buttons flash three times.
IP Settings
Reset
Absolute
Reset
Events
Reset
(Mode 5)
(Mode 4)
(Mode 3)
Release, then immediately
press and release again.
Figure 26.
Soft System Resets