Remote port, Ethernet port, Remote port ethernet port – Extron Electronics DMS 1600_2000_3200_3600 User Guide User Manual
Page 17

DMS 1600, DMS 2000, DMS 3200, and DMS 3600 • Installation
11
c
Fiber optic input ports — Connect fiber optic cables to the Input LC
connectors.
Connect the opposite ends of these fiber optic cables to the Output connectors on
DFX 100 Tx transmitters.
Input LEDs — Amber indicates fiber connections.
Green indicates input signal detection.
d
Fiber optic output ports — Connect fiber optic cables to the Input LC
connectors.
Connect the opposite ends of these fiber optic cables to the Input connectors on
DFX 100 Rx receivers.
Input LEDs — Amber indicates fiber connections.
Green indicates signal transmission.
Remote Port
e
Remote RS-232/RS-422 port — Connect a host device, such as a computer, touch
panel control, or RS-232 capable PDA to the switcher via this 9-pin D connector for
serial RS-232/RS-422 control (see figure 9).
RS-232 Function
Pin
Function
1
2
3
4
5
6
7
8
9
—
TX
RX
—
Gnd
—
—
—
—
Not used
Transmit data
Receive data
Not used
Signal ground
Not used
Not used
Not used
Not used
—
TX–
RX–
—
Gnd
—
RX+
TX+
—
Not used
Transmit data (–)
Receive data (–)
Not used
Signal ground
Not used
Receive data (+)
Transmit data (+)
Not used
RS-422
1
5
6
9
REMO
TE
RS-232/RS-422
Figure 9.
Remote RS-232/RS-422 Port
See
, starting on page 46 for definitions of the SIS commands
starting on page 61 for details on the control software.
NOTE: The switcher can support either the RS-232 or RS-422 serial protocol, and
can operate at 9600, 19200, 38400, or 115200 baud rates.
See
Selecting the Rear Panel Remote Port Protocol and Baud Rate
to configure the RS-232/RS-422 port from the front panel.
If desired, connect an MKP 2000 or MKP 3000 remote control panel to the rear panel
Remote port on the switcher. See the MKP 2000 Remote Control Panel User Guide or
the MKP 3000 User Guide for details.
Ethernet Port
f
LAN port — If desired, for IP control of the system, connect the matrix
LAN
LINK
AC
T
switcher to a PC or to an Ethernet LAN via this RJ-45 connector. You can use
a PC to control the networked switcher with SIS commands from anywhere in
the world. You can also control the switcher from a PC that is running the Extron Matrix
Switchers Control Program or has downloaded HTML pages from the switcher.
Link LED indicator — Indicates that the switcher is properly connected to an
Ethernet LAN. This LED should light steadily.
Act LED indicator — Indicates transmission of data packets on the RJ-45 connector.
This LED should flicker as the switcher communicates.